Matthew Showers is an HVAC service technician, performing work in both the residential and commercial fields. His specialty is in inverter and communicating systems. Follow Matt on Instagram As environmental regulations change, manufacturers of HVAC equipment are being forced to find refrigerants that are not only environmentally safe, but also perform…
-
Alternative Refrigerants For The HVAC Industry
CLICK HERE TO READ THE FULL ARTICLE »
-
HVAC Tip - IAQ and Carbon Dioxide
As I read posts and comments within social media HVAC groups regarding indoor air quality or IAQ it is clear that most technicians are focused on clean, healthy homes for their customers and their own families. The main discussion revolves around filtration systems, temperature, humidity and air purification. There is…
CLICK HERE TO READ THE FULL ARTICLE »
-
HVAC Tip - Replace Refrigerant Hose Seals On The Regular
To some HVAC technicians, replacing hose seals or gaskets is actually a foreign concept, hose maintenance you say? Hose maintenance is an integral part of successful day to day service and installation. If hose seals become compressed or broken, we can have leaks while testing or evacuating, I have also…
CLICK HERE TO READ THE FULL ARTICLE »
-
Asco Acetylene Torch Kit
In this video review for TruTech Tools I test out the Asco Acetylene Torch Kit. With this kit, there is no need for oxygen in your torch set up. Check out this link to read TruTech Tool's info on this great product. Save 8% on your purchase of this kit…
CLICK HERE TO READ THE FULL ARTICLE »
-
HVAC Tip: Set Screw Tightening
During my career I have come across many pulleys, shafts, blower wheels and bearings that have come loose due to improper set screw tightening, sadly a lot of this equipment was brand new or close to new. On some larger equipment or equipment that may be susceptible to excessive vibration,…
CLICK HERE TO READ THE FULL ARTICLE »
-
HVAC Tip: Fastening Rooftop Unit Panel Tabs
As a commercial tech, I have worked on many models and types of rooftop equipment. One major problem I have noticed over the years is panels not staying put, sometimes it's the fault of the tech forgetting to fasten the screws. Sometimes it's due to stripped screws that go unnoticed…
CLICK HERE TO READ THE FULL ARTICLE »
-
HVAC Tip: Preparing Wires For Twist On Connectors
Tip: Preparing Wires For Twist On Connectors By: Gary McCreadie Have you ever come across twist on connectors that have fallen off or when you twist them on, some wiring breaks off inside and leaves the connector useless? The following video demonstrates a sure fire way to ensure the wires stay intact. Some techs…
CLICK HERE TO READ THE FULL ARTICLE »